SMARTPILLAR®
PDMS micropillar coverslips for cell force measurement
SmartPillar coverslips are 16 mm glass substrates featuring microfabricated polydimethylsiloxane (PDMS) micropillar arrays for cell culture, traction force microscopy and cellular contractility studies.
Cells exert forces on the flexible micropillars, causing measurable deflections that can be used to estimate cellular forces when combined with appropriate pillar stiffness calibration and image analysis.
Available in different geometries, heights and arrangements, SmartPillar coverslips support mechanobiology research, cell–substrate interaction studies and investigations of cellular responses to mechanical cues.

KEY FEATURES OF SMARTPILLAR COVERSLIPS
Multiple micropillar geometries
Choose between round, square and banded PDMS micropillar arrays, with different pillar dimensions and heights to suit specific experimental requirements.
Micropillar-based force sensing
Cell-generated forces induce pillar deflections that can be analyzed to estimate local traction forces and cellular contractile activity.
Compatible with high-resolution microscopy
Glass-supported micropillar arrays enable optical observation of cells and pillar displacement during experiments.
Designed for cell culture
Each coverslip is supplied in an individual Petri dish with a removable silicone stencil. Adhesion protein coating can be performed when required by the cell type.
HOW DO PDMS MICROPILLAR ARRAYS MEASURE CELLULAR FORCES?
PDMS micropillar arrays are microstructured elastic substrates used to investigate how cells interact mechanically with their environment.
When cells adhere to and exert traction on the pillars, the pillars bend in response to the applied forces. Their displacement can be measured using optical microscopy.
For a pillar behaving as a linear elastic spring, the applied lateral force can be estimated from its displacement and calibrated spring constant:
Force = pillar stiffness × pillar displacement
Micropillar geometry, including height and cross-sectional dimensions, influences mechanical stiffness and therefore the force range that can be investigated.
Unlike continuous elastic substrates, micropillar arrays provide individual deformable elements that can be tracked to study local cell–substrate forces.
TECHNICAL SPECIFICATIONS
Specifications | SmartPillar Coverslips |
|---|---|
Substrate | Glass coverslip with microfabricated PDMS micropillars |
Coverslip diameter | 16 mm |
Glass thickness | Approximately 170 µm |
Micropillar array area | 5 × 5 mm, positioned centrally |
Available configurations | Round pillars, bands of pillars and square pillars |
Imaging | Compatible with high-resolution optical microscopy |
Packaging | Individual 35 mm glass-bottom Petri dish |
Included accessory | Removable silicone stencil to facilitate cell seeding and reagent incubation |
Surface functionalization | Optional adhesion protein coating, including fibronectin, collagen or laminin |
Storage | Up to 6 months under the conditions specified in the User Guide |
STANDARD PDMS MICROPILLAR CONFIGURATIONS
SmartPillar coverslips are available with three standard micropillar configurations. Each design provides different pillar dimensions, spacing and height options to accommodate specific cell culture and mechanobiology experiments.
Round PDMS micropillar arrays
-
Pillar shape: Circular
-
Pillar diameter: 5 µm
-
Center-to-center spacing: 12 µm
-
Available pillar heights: 2, 6 and 12 µm
Product Reference | Pillars Height (µm) |
|---|---|
MPL-ROUND-12 | 12 |
MPL-ROUND-06 | 6 |
MPL-ROUND-02 | 2 |

Three height options enable the selection of different micropillar geometries and mechanical responses.
Banded PDMS micropillar arrays
This configuration combines two micropillar designs arranged in separate bands, each 1 mm wide, on the same coverslip.
Product Reference | Pillars Height (µm) |
|---|---|
MPL-BAND-02 | 2 |
Band 1
Band 2

-
Pillar diameter: 4 µm
-
Center-to-center spacing: 8 µm
-
Pillar diameter: 2 µm
-
Center-to-center spacing: 4 µm
Available pillar height: 2 µm for both designs.
Square PDMS micropillar arrays
-
Pillar shape: Square
-
Pillar width: 7.5 µm
-
Interpillar distance: 20 µm
-
Available pillar heights: 2, 6 and 12 µm
Product Reference | Pillars Height (µm) |
|---|---|
MPL-SQUARE-12 | 12 |
MPL-SQUARE-06 | 6 |
MPL-SQUARE-02 | 2 |

Square micropillar arrays provide an alternative cross-sectional geometry for investigating cellular mechanical interactions.
APPLICATIONS OF PDMS MICROPILLAR COVERSLIPS
Traction force microscopy
Investigate forces exerted by adherent cells on their substrate by measuring the displacement of individual micropillars.
Cell contractility studies
Characterize cellular mechanical activity, including changes in contractile behavior under different experimental conditions.
Cell mechanosensing and substrate stiffness
Study cellular responses to mechanical properties of the substrate using micropillar configurations with different mechanical characteristics.
Cell migration and mechanobiology
Investigate cell–substrate interactions, adhesion and force generation during cellular movement.
Cardiomyocyte contractility research
Explore cellular contraction and mechanical responses in cardiomyocyte-based experimental models using appropriately designed micropillar configurations.
Explore cell-based applications
Discover how 4Dcell's micropillar technology can be used to investigate cell-generated forces and mechanical responses in different biological models.
Explore our single cardiomyocyte contractility assay to learn how micropillar-based approaches enable the measurement of cardiomyocyte contraction forces.
HOW TO USE SMARTPILLAR COVERSLIPS
SmartPillar coverslips are supplied in individual 35 mm Petri dishes with a removable silicone stencil positioned around the micropillar area.
Depending on the cell type, the micropillars can be functionalized with adhesion proteins such as fibronectin, collagen or laminin before cell seeding.
After appropriate preparation, cells are seeded onto the micropillar region and cultured under conditions adapted to the experimental model. Micropillar displacement can then be observed using optical microscopy.
Important handling precaution: Once the micropillars have been wetted, they must remain wet throughout sample preparation. Drying can cause irreversible pillar collapse due to capillary forces.
For the complete preparation and cell-seeding procedure, consult the SmartPillar Coverslip User Guide.
FORCE MEASUREMENT & DATA ANALYSIS
SmartPillar coverslips provide a physical substrate for studying cell-generated forces through micropillar deformation.
Quantitative force measurements require suitable microscopy acquisition, pillar displacement analysis and knowledge of the mechanical stiffness of the selected micropillar configuration.
Analysis software is not included with SmartPillar coverslips. Researchers should use an appropriate image analysis workflow and force calibration method for their experimental conditions.
Contact 4Dcell to discuss the choice of micropillar geometry and its suitability for your intended application.
CUSTOM PDMS MICROPILLAR ARRAYS
Looking for micropillar dimensions or arrangements beyond our standard catalog?
4Dcell offers customized micropillar designs to address specific experimental requirements, including pillar geometry, height and spatial arrangement.
Our team can help you identify a suitable configuration for your cell type, microscopy setup and mechanobiology application.
Contact our team to discuss your specifications or request a quotation.
FREQUENTLY ASKED QUESTIONS
SCIENTIFIC REFERENCES
Trichet, L. et al. (2012). Evidence of a large-scale mechanosensing mechanism for cellular adaptation to substrate stiffness. Proceedings of the National Academy of Sciences, 109(18), 6933–6938. https://doi.org/10.1073/pnas.1117810109
Gupta, M. et al. (2015). Micropillar substrates: A tool for studying cell mechanobiology. Methods in Cell Biology, 125, 289–308. https://doi.org/10.1016/bs.mcb.2014.10.009