top of page

SMARTCHANNELS®

Ready-to-use PDMS microchannel dishes for cell migration assays

SmartChannel Dishes are 35 mm glass-bottom Petri dishes containing pre-bonded PDMS microchannels designed to study cell migration, deformation, and behavior under geometrical confinement.

​

Available with straight channels or constrictions of different dimensions, these devices allow researchers to investigate how physical constraints influence individual cells and collective migration.

​

The microchannels are supplied pre-assembled, eliminating the need for in-house microfabrication. Simply wash the device, apply the appropriate extracellular matrix coating, seed your cells, and monitor their behavior by live-cell microscopy.

4Dcell SmartChannel 35 mm glass-bottom Petri dish with pre-bonded PDMS microchannels.
SmartChannel PDMS microchannel technology for studying cell migration and geometrical confinement.

WHY CHOOSE SMARTCHANNEL DISHES?

Ready-to-use microchannels

PDMS microchannels are already bonded to the glass-bottom dish. No molding, plasma bonding, or dedicated microfabrication equipment is required before use.

Controlled geometrical confinement

Different channel widths, heights, and constriction geometries enable researchers to investigate how spatial constraints influence cell migration, morphology, and deformation.

Compatible with live-cell imaging

The approximately 170 µm glass bottom supports optical observation through the dish, including time-lapse fluorescence and high-resolution microscopy with compatible objectives.

Flexible experimental designs

Choose among standard microchannel geometries or discuss customized dimensions with 4Dcell to accommodate specific cell types and experimental requirements.

HOW DO SMARTCHANNEL DISHES CONTROL CELL MIGRATION?

SmartChannel Dishes contain PDMS microstructures bonded to a glass substrate, creating enclosed microchannels through which cells can migrate.

​

The width and height of each channel define the available space for cell movement. Narrow channels and constrictions create geometrical confinement, requiring migrating cells to adapt their shape and deform cellular structures, including the nucleus.

​

By selecting different channel geometries, researchers can compare cell migration under varying physical constraints and examine changes in cell speed, morphology, directionality, and deformation.

​

The glass-bottom configuration allows these responses to be observed by microscopy, providing a controlled experimental environment for investigating cell migration and mechanobiology.

APPLICATIONS OF MICROCHANNEL DISHES IN CELL RESEARCH

Cell migration and invasion

Investigate individual or collective cell migration through channels of defined dimensions. Compare migration speed, cell morphology, and responses to different levels of geometrical confinement.

Immune cell migration

Study how immune cells navigate confined environments, including narrow passages relevant to tissue infiltration and immune-cell motility.

Nuclear deformation and mechanobiology

Examine changes in nuclear morphology and cell deformation during migration through microchannels and constrictions. These experiments can help investigate the relationship between cellular mechanics and migration behavior.

Cancer cell migration

Explore how cancer cells migrate through confined spaces and how cellular deformability influences their ability to pass through narrow geometrical structures.

Cell migration under experimental treatments

Compare migration responses between control and treated cells to investigate how selected perturbations affect motility and the ability to traverse confined environments. Compound compatibility with PDMS should be assessed when designing these studies.

TECHNICAL SPECIFICATIONS

Specifications
Smartchannel dishes
Product
SmartChannel Dishes
Dish format
35 mm glass-bottom Petri dish
Microchannel material
PDMS (polydimethylsiloxane)
Glass thickness
Approximately 170 µm
Channel configuration
Enclosed PDMS microchannels bonded to glass
Available geometries
Straight channels and channels with constrictions
Channel widths
Range advertised from 2 to 1000 µm, depending on design
Constriction example
1.5 µm width
Access ports
9 per chip, according to the standard configuration
Channel size ranges
Distinct channel-width ranges | 6 per chip, according to the standard configuration
Packaging
Individually packed in sterile plastic bags
Ordering formats
Sets of 20 or 50 dishes
Customization
Alternative dimensions and geometries upon request

AVAILABLE MICROCHANNEL GEOMETRIES & REFERENCES

SmartChannel Dishes are available in several standard configurations, allowing researchers to select channel geometries adapted to their cell migration experiments.

Straight microchannels

Straight microchannels provide defined migration paths for investigating cell movement under geometrical confinement.

  • MC001, MC002, MC003 and MC004: small microchannel designs available with different channel heights.

  • MC005: medium microchannel design.

These configurations can be used to compare cell migration under different spatial constraints.

Small size microchannels

Product reference
Channel height (µm)
Channel width (µm)
MC001
2.5
2
MC001
2.5
3
MC001
2.5
4
MC001
2.5
5
MC001
2.5
6
MC001
2.5
8
MC002
3
2
MC002
3
3
MC002
3
4
MC002
3
5
MC002
3
6
MC002
3
8
Product reference
Channel height (µm)
Channel width (µm)
MC003
4
2
MC003
4
3
MC003
4
4
MC003
4
5
MC003
4
6
MC003
4
8
MC004
5
2
MC004
5
3
MC004
5
4
MC004
5
5
MC004
5
6
MC004
5
8

Medium size microchannels

Product reference
Channel height (µm)
Channel width (µm)
MC005
10
10
MC005
10
12
MC005
10
14
MC005
10
16
MC005
10
18
MC005
10
20

Large size microchannels

Product reference
Channel height (µm)
Channel width (µm)
MC006
25
50
MC007
25
100
MC008
25
200
MC009
25
400
MC010
25
1000
Schematic of small straight PDMS microchannels available in different heights, references MC001 to MC004.

Small microchannels chip design available in different heights (MC001, MC002, MC003, MC004).

Schematic of medium-sized straight PDMS microchannel geometry, SmartChannel reference MC005.

Medium microchannels chip design (MC005)

Microchannels with constrictions

Constricted microchannels contain narrow passages along the migration path, enabling the investigation of cell and nuclear deformation during migration.

  • MC011: medium microchannel design with constrictions.

  • MC012, MC013, MC014 and MC015: constricted microchannel designs available with different heights.

SmartChannel geometries include narrow constrictions, with an illustrated example of a 1.5 µm-wide passage.

The selection of channel width, height, and constriction geometry should be based on the cell type, expected migration behavior, and experimental objectives.

Microchannels with constrictions

Product reference
Channel height (µm)
Channel width (µm)
Channel length (µm)
Constriction width (µm)
Constriction length (µm)
MC011
10
12
150
3, 4, 5, 6, 7, 8
5
MC012
2.5
5
150
1.5, 2, 2.5, 3, 3.5, 4
15
MC013
3
5
150
1.5, 2, 2.5, 3, 3.5, 4
15
MC014
4
5
150
1.5, 2, 2.5, 3, 3.5, 4
15
MC015
5
5
150
1.5, 2, 2.5, 3, 3.5, 4
15
MC016
2.5
8
150
1.5, 2, 2.5, 3, 4, 5
15
MC017
3
8
150
1.5, 2, 2.5, 3, 4, 5
15
MC018
4
8
150
1.5, 2, 2.5, 3, 4, 5
15
MC019
5
8
150
1.5, 2, 2.5, 3, 4, 5
15
Schematic of PDMS microchannels with constrictions available in different heights, references MC012 to MC015.

Microchannels chip design with constrictions available in different heights (MC012, MC013, MC014, MC015).

Schematic of medium-sized PDMS microchannels with constrictions, SmartChannel reference MC011.

Medium microchannels chip design with constrictions (MC011)

Example of a 4Dcell microchannel with a constriction of 1.5 µm width.

Technical schematic showing the dimensions of a SmartChannel PDMS microchannel with constrictions, including channel width and constriction geometry.
Schematic of the negative mold used to fabricate medium-sized PDMS microchannels with constrictions, SmartChannel reference MC011.

Custom microchannel designs

4Dcell can discuss customized microchannel dimensions and geometries for research applications requiring configurations beyond the standard catalog.

​

Contact our team to identify the most appropriate SmartChannel reference for your experiment.

EXPERIMENTAL CONSIDERATIONS

The selection of channel geometry and surface coating should be adapted to the cell type and the biological question being investigated.

 

For experiments involving soluble compounds, the potential absorption of molecules by PDMS should be considered during study design. Appropriate equilibration, controls, or preliminary compatibility assessments may be necessary.

​

Channel dimensions impose geometrical constraints but do not, by themselves, provide a direct quantitative measurement of the mechanical forces experienced by cells.

​

Researchers should also verify compatibility between their microscopy objectives, experimental protocol, and selected microchannel geometry.

HOW TO PREPARE SMARTCHANNEL DISHES FOR CELL MIGRATION ASSAYS

SmartChannel Dishes are supplied with PDMS microchannels already bonded to a glass-bottom Petri dish, eliminating the need for microfabrication or assembly.

​

The preparation workflow involves washing the microchannels, applying an extracellular matrix coating, equilibrating the device with culture medium, and seeding the cells before incubation and imaging.

​

The illustrated protocol below outlines the main preparation steps. For detailed instructions, including recommended volumes, incubation times, and cell seeding conditions, consult the SmartChannel Dishes User Guide.

Six-step illustrated protocol for preparing SmartChannel PDMS microchannel dishes for cell migration experiments.

FREQUENTLY ASKED QUESTIONS

LOOKING TO FABRICATE YOUR OWN MICROCHANNELS?

While SmartChannel Dishes provide ready-to-use PDMS microchannels, the SmartChannel Fabrication Kit enables researchers to manufacture their own microchannel devices in the laboratory.

​

Explore our fabrication solution for greater flexibility in producing microchannels adapted to your experimental needs.

FIND THE RIGHT MICROCHANNEL GEOMETRY FOR YOUR EXPERIMENT

Whether you are investigating confined cell migration, nuclear deformation, or immune cell motility, 4Dcell can help you select a SmartChannel configuration adapted to your research objectives.

​

Explore our standard microchannel geometries or contact our team to discuss specific dimensions, experimental requirements, availability, and ordering options.

bottom of page